Skip to content
Entourage

How does your novel device get its own FDA classification through De Novo?

We support medical device and IVD manufacturers through the De Novo request, from the search for a possible predicate to the FDA decision. The request must show that the device type is new and that general controls, for class II with special controls, address its risks.

Overview

Where does a De Novo request fail?

De Novo classification for medical devices and IVD · FD&C Act Sec. 513(f)(2) · 21 CFR 860.200 to 860.260 · FDA guidance on the De Novo process, the De Novo eSTAR and benefit-risk determinations

Last updated: October 31, 2026

FDA reviews a De Novo request in two stages. First it asks whether the device type already exists, then whether general controls, or general and special controls, provide reasonable assurance of safety and effectiveness. The request can end at either stage; 21 CFR 860.260(c) lists eleven grounds for declining it.

  • The search misses a device type. The request itself must contain the searches, the similar devices from classification regulations, 510(k)s, PMAs, HDEs and EUAs, and the rationale for how the device differs (21 CFR 860.220(a)(8)). If FDA still finds a predicate during substantive review, it declines the request and the route leads to a 510(k).
  • The 510(k) failed only on data. After an NSE determination, FDA considers a De Novo request when the NSE rests on a missing predicate, a new intended use or technology that raises different questions of safety and effectiveness. If only performance data were lacking, the De Novo guidance (October 5, 2021) generally rules the route out.
  • Risks and controls are not linked. Every known risk needs a mitigation and, where that rests on testing or labeling, a reference to the section of the request holding the evidence (21 CFR 860.220(a)(9)). For class II, the statute requires an initial draft of the special controls with a rationale (Sec. 513(f)(2)(A)(v)).
  • The device changes during review. If the requester makes significant unsolicited changes to the indications for use or technological characteristics after acceptance, FDA may decline (21 CFR 860.260(c)(11)). New safety and effectiveness information from ongoing studies, on the other hand, must be submitted (21 CFR 860.220(d)).

Industries

What this means in your industry

Select an industry

Medical Devices

What applies
21 U.S.C. 360c(f)(2) and 21 CFR Part 860 Subpart D; nonclinical data under 21 CFR 860.220(a)(15)(i), such as biocompatibility, shelf life, electrical safety and EMC, labeling under 21 CFR Part 801.
Who audits
FDA, for most devices CDRH; for devices regulated by CBER, its submission route applies (21 CFR 860.210(a)(1)).

IVD

What applies
The same regulations; labeling must comply with 21 CFR Part 809, otherwise FDA may decline the request (21 CFR 860.260(c)(3)).
Who audits
FDA, CDRH or CBER depending on the product, with the submission route under 21 CFR 860.210(a)(1).

Services

How we support you

Eligibility check and classification search

Search of classification regulations in 21 CFR Parts 862 to 892, product codes, 510(k)s, PMAs, HDEs, EUAs and granted De Novo requests, with the search terms on record. Deliverable: the classification summary under 21 CFR 860.220(a)(8), which explains for each similar device how your device type differs.

Risk analysis and special controls

Mapping each known risk to health to a mitigation, separated into general and special controls, with a reference to the testing or labeling in the request that supports it. For class II, we write the draft special controls the way they later appear in the classification regulation: as requirements on data, software and labeling for the whole device type.

Benefit-risk assessment and evidence plan

Planning the nonclinical and, where needed, clinical data that show the probable benefit outweighs the probable risk under the proposed controls (21 CFR 860.7, 860.220(a)(14)). Assessed against the factors in FDA's guidance of August 30, 2019: type, magnitude, probability and duration of benefit, severity, rates and duration of harm, and the uncertainty of the data.

Building the request in the eSTAR

Building the request under 21 CFR 860.220 in the De Novo eSTAR: regulatory history with all prior submissions, indications for use, device description, alternatives, classification recommendation, standards, study summaries and technical sections. Whatever does not apply to the device is listed as a justified omission in a separate section (21 CFR 860.220(c)).

Support through the decision

Support through technical screening, interactive review and additional information requests, each response complete and within the 180 days of 21 CFR 860.250(a)(1). Preparation for an inspection before the decision under 21 CFR 860.240(c). After a decline, the assessment of whether a new request with more data, a 510(k) or a PMA is the way forward.

What it comes down to

A device of a new type is in class III by operation of law, regardless of its risk (FD&C Act Sec. 513(f)(1)). The De Novo request under Sec. 513(f)(2) is the way out: FDA classifies the device type into class I or II under the criteria of Sec. 513(a)(1) and thereby creates a classification regulation that did not exist before.

21 CFR 860.220(a) lists what the request must contain in 19 items. An item that is left out needs a justification; otherwise FDA may refuse the request at acceptance review (21 CFR 860.230(c)(1)(ii)).

Part of the requestContent21 CFR 860.220(a)
Contextregulatory history, indications for use, device description, alternative practices and procedures(3) to (7)
Classificationsearches, similar devices, rationale for the difference; after an NSE determination, the 510(k) number and the search since then(8)
Risks and controlsrisks with mitigations, draft special controls, recommended class with rationale(9) to (11)
Evidencestandards, study summaries, benefit and risk, technical sections with test reports(12) to (15)
Otherliterature, samples on request, labeling and advertisements(16) to (19)

21 CFR 882.5804 shows what the result looks like. The regulation identifies a device type in one sentence and sets class II with three special controls, one requirement each on clinical data, software verification and labeling. FDA had granted the request on May 9, 2023; the device type entered the CFR with the notice of June 26, 2026. A search limited to 21 CFR Parts 862 to 892 would have missed it for three years.

Outside this page are the choice between 510(k), De Novo and PMA on the page FDA Strategy & Pathways, the 510(k) itself, the qualification of a product as a medical device or IVD before the pathway choice, and preparation for FDA inspections under the QMSR.

Our approach

Our approach

01

Clarify eligibility

A recorded search without a predicate, classification regulation or PMA for the device type, and the choice between a direct request and a prior 510(k).

02

Submit a Pre-Sub

FDA feedback on eligibility, risks, controls and test protocols before the studies begin.

03

Generate evidence

Nonclinical and, where needed, clinical data for each mitigation, with summaries under 21 CFR 860.220(a)(13).

04

Submit the request

An eSTAR that passes technical screening, with the classification recommendation and, for class II, the draft special controls.

05

Act on the decision

If granted, a new classification regulation whose special controls your device and every later 510(k) of the same type must meet; if declined, a reasoned next route.

Common pitfalls

Where projects commonly fail

Another manufacturer is faster.

If FDA grants a De Novo request for the same device type while yours is still under review, it declines yours under the De Novo guidance (October 5, 2021). The data can be incorporated by reference into a 510(k), which then names the first device as predicate and has to meet the new special controls.

Something else is still open for the same device.

FDA may refuse a De Novo request at acceptance review if another submission or a reclassification petition for the device is pending or deficiencies from earlier submissions remain unanswered (21 CFR 860.230(c)(1)(i) and (v)).

The special controls are written only for your own device.

After the grant they apply to the whole device type and are published with the classification in the Federal Register (21 CFR 860.260(a)(2)); your own next generation has to meet them in its 510(k) as well.

Labeling comes last.

Labels, labeling and advertisements are part of the request (21 CFR 860.220(a)(18)), and labeling that does not comply with 21 CFR Part 801 or, for IVD, Part 809 is a ground for declining in its own right (21 CFR 860.260(c)(3)).

Regulatory Affairs

Do any of these pitfalls apply to you?

In a first call we assess your situation and say what needs clarifying first in your case. Without obligation, reply usually within one working day.

FAQ

Frequently asked questions

No. Besides the request after an NSE determination, there is the direct request when the manufacturer determines that there is no legally marketed device on which to base substantial equivalence (FD&C Act Sec. 513(f)(2)(A)(ii), 21 CFR 860.200(b)). Without a prior 510(k) and without a Pre-Sub, success depends more, according to the De Novo guidance, on how thoroughly you searched for a predicate.

Sources
  • 21 CFR Part 860 Subpart D, §§ 860.200 to 860.260, and §§ 860.3 and 860.7 (eCFR, as of October 27, 2026): https://www.ecfr.gov/current/title-21/chapter-I/subchapter-H/part-860/subpart-D
  • Federal Food, Drug, and Cosmetic Act Sec. 513(a)(1) and 513(f), 21 U.S.C. 360c(a)(1) and 360c(f) (U.S. Code, 2024 edition, govinfo)
  • 21 CFR 882.5804, example of a classification regulation with special controls that originated in De Novo (eCFR, as of October 27, 2026; Federal Register 91 FR 38510 of June 26, 2026)
  • FDA Guidance: De Novo Classification Process (Evaluation of Automatic Class III Designation) (October 5, 2021): https://www.fda.gov/media/72674/download
  • FDA Guidance: Electronic Submission Template for Medical Device De Novo Requests (August 23, 2024): https://www.fda.gov/media/172450/download
  • FDA Guidance: Factors to Consider When Making Benefit-Risk Determinations in Medical Device Premarket Approval and De Novo Classifications (August 30, 2019): https://www.fda.gov/media/99769/download
  • FDA: De Novo Classification Request (web page, content current as of September 30, 2025): https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/de-novo-classification-request

Image notice: The images on this page were generated using artificial intelligence. They do not depict real people, places, or events.

Regulations & standards considered

  • FD&C Act Sec. 513(f)(2), 21 U.S.C. 360c(f)(2) (De Novo classification)
  • FD&C Act Sec. 513(a)(1), 21 U.S.C. 360c(a)(1) (classes I, II and III)
  • 21 CFR 860.3 (definitions of class I to III, general controls, special controls)
  • 21 CFR 860.7 (valid scientific evidence, benefit and risk)
  • 21 CFR 860.200 (purpose, the two routes to a request)
  • 21 CFR 860.210 and 860.220 (format and content of the request)
  • 21 CFR 860.230 (acceptance review)
  • 21 CFR 860.240 and 860.250 (review, additional information, withdrawal)
  • 21 CFR 860.260 (granting or declining)
  • FDA guidance: De Novo Classification Process (Evaluation of Automatic Class III Designation) (October 5, 2021)
  • FDA guidance: Electronic Submission Template for Medical Device De Novo Requests (August 23, 2024)
  • FDA guidance: Factors to Consider When Making Benefit-Risk Determinations in Medical Device Premarket Approval and De Novo Classifications (August 30, 2019)

Have a concrete project?

Briefly outline your situation. We'll respond with an initial assessment, usually within one business day.

Prefer direct? +49 89 4161170-0
contact@theentourage.de

  • Reply usually within one working day
  • 4 locations: DE · CH · IT · US
  • 100% life sciences