Skip to content
Entourage

How does your FDA Q-Sub get answers you can build the submission on?

We prepare FDA Q-Submissions for medical device and IVD manufacturers, from choosing the Q-Sub type through the questions to the meeting minutes. In a Pre-Sub, the FDA answers specific questions on your proposal; it does not pre-review data or decide on classification.

Overview

Why does a Pre-Sub return an answer nobody can use?

Q-Submission Program for medical devices and IVD · FDA guidance of May 29, 2025 · Pre-Sub, SIR, Study Risk Determination, Informational Meeting, PMA Day 100 Meeting · 21 CFR 812.2

Last updated: November 1, 2026

The FDA answers in a Pre-Sub only what it was asked, and only for the information it was given. Most weak answers trace back to the request itself.

  • The question asks for an outcome. “Will this proposal support a determination of substantial equivalence?” or “Can FDA confirm my device is eligible for a 510(k) or De Novo?” are among the questions the guidance does not recommend (Appendix 2). Classification belongs in a 513(g) request for information; in a Pre-Sub the FDA comments on a concrete proposal, for instance whether a cleared device can serve as the predicate.
  • The Pre-Sub carries too many topics. The FDA has found it difficult to address more than three or four substantial topics in one Pre-Sub, such as biocompatibility, an animal study or the statistical analysis plan; the most effective Pre-Subs have no more than 7 to 10 questions including sub-questions (guidance, Section III.B(4)a).
  • The questions depend on decisions that are still open. Asking about performance testing before the indications for use and the pathway are settled, or while the design is still changing, may be premature in the FDA's view; the feedback on the dependent questions then stays general.
  • The request does not pass acceptance. Within 15 days the FDA checks four points: purpose, device description, specific questions and a planned follow-on submission. Questions on a file under active review lead to a Refuse to Accept; questions on a hold letter are converted to a Submission Issue Request. After an RTA hold the clock restarts at day 0.

Industries

What this means in your industry

Select an industry

Medical Devices

What applies
Q-Submission guidance of May 29, 2025, for Pre-Subs before an IDE, PMA, HDE, De Novo request or 510(k); for clinical investigations, the risk determination under 21 CFR 812.2(b).
Who audits
The FDA, for most devices CDRH (Q numbers); for devices regulated by CBER, its regulatory project manager assigns a BQ number.

IVD

What applies
The same guidance; a Pre-Sub can also prepare a CLIA Waiver by Application or a Dual 510(k) and CLIA Waiver. Diagnostic studies may be exempt from most IDE requirements under 21 CFR 812.2(c)(3); a Study Risk Determination settles it.
Who audits
The FDA, CDRH or CBER depending on the device, with the same Q-Sub processes.

Services

How we support you

Q-Sub type and sequence

Choosing the type that fits the question: Pre-Sub before a planned submission, Submission Issue Request after a hold letter, Study Risk Determination for a clinical investigation, Informational Meeting without feedback. Several Q-Subs for one device are planned as an original with supplements, one at a time, with the overview of further Q-Subs in the first.

Formulating the questions

Turning open questions into proposals the FDA can answer: a proposed test method, animal model or endpoint with its rationale, references to guidance, standards and earlier FDA feedback, and the labeling claim the evidence is meant to support. Deliverable: a list of no more than ten questions, each naming the decision in the project it informs.

Pre-Sub package

Cover letter with Q-Sub type, method of feedback and, for a meeting, draft agenda, format, three or more dates and the planned attendees; in the body purpose, device description, indications for use, regulatory history and the planned follow-on submission. Background goes in where a question needs it, in English, as an eCopy or voluntarily as a PreSTAR.

Meeting preparation

Reading the written feedback, which arrives at least 5 days before the meeting, and narrowing the agenda to the questions it leaves open. Slides go to the FDA at least two days ahead; the meeting is normally limited to one hour. Where statistics are on the agenda, the request can suggest that an FDA statistician attend.

Minutes and follow-through

Drafting the minutes as an amendment within 15 days of the meeting: discussion summarized, agreements and action items listed, statements assigned to the FDA or the company, not to individuals. Afterwards the feedback goes into the test plan and, in the later submission, into a section that cites the Q-Sub and explains how each point was addressed.

Submission Issue Request

After an Additional Information letter for a 510(k) or De Novo, a Major Deficiency letter for a PMA or an IDE letter: a SIR on the planned approach, with the deficiencies named and, where new data are planned, a proposed protocol with its rationale. Written feedback or a meeting, not both; the due date of the response stays where it is.

What it comes down to

A Q-Submission is the FDA's tracking system for requests for feedback or a meeting on a medical device submission. The guidance of May 29, 2025, covers five types in detail; others, such as Breakthrough designation requests or STeP entrance requests, run through the same system under their own guidance. Taking part is voluntary, and no Q-Sub obliges the manufacturer to file a later submission.

Q-Sub typeFor whatHow the FDA answersTimeframe in the guidance
Pre-Submissionspecific questions before a planned IDE, 510(k), De Novo request, PMA, HDE or CLIA waiverwritten feedback, optionally followed by a meeting70 days, or 5 days before the meeting if that is sooner
Submission Issue Requestthe approach to the deficiencies in a hold letterwritten feedback or a meeting21 days if received within 60 days of the letter, otherwise 70, as resources permit
Study Risk Determinationwhether a planned clinical investigation is significant risk, nonsignificant risk or exemptformal letter90 days
Informational Meetinginformation for the FDA without feedback, for instance on several submissions planned in the next 6 to 12 monthsmeeting90 days, as resources permit
PMA Day 100 Meetingthe review status of a filed PMAmeeting, with the deficiencies found so far in writing beforehand100 days from the filing date

The first Q-Sub for a device and its indications for use becomes the original; at CDRH it receives a number such as Q180001. Every further request on the same device is a supplement (Q180001/S001), every addition without a new request, such as slides or minutes, an amendment. The guidance recommends one Q-Sub per device at a time, because feedback on one can change the answers to another.

The Pre-Sub is not a pre-review. The FDA does not review data in it, does not design studies and does not discuss a file it is currently reviewing; that runs through interactive review. Its answer is best advice at a point in time, which is why the FDA finds feedback most useful before planned testing starts.

This page leaves out the choice of pathway and the programs Breakthrough, STeP and TAP, both covered on FDA Strategy & Pathways, as well as the submissions the Pre-Sub prepares: 510(k), De Novo and PMA. Meetings for medicinal products are described under Health Authority Interaction.

Our approach

Our approach

01

Set the goal and the type

One Q-Sub type, the follow-on submission it prepares, and the place of this Q-Sub in the sequence for the device.

02

Formulate the questions

Up to four substantial topics with a proposal, rationale and references for each question.

03

Submit and pass acceptance

A Pre-Sub that passes acceptance review or technical screening, with a confirmed or offered meeting date.

04

Prepare and hold the meeting

An agenda reduced to the open points, slides at the FDA two days ahead, and a team that knows who answers which question.

05

Record and apply

Minutes submitted within 15 days and FDA feedback built into the test plan and the later submission.

Common pitfalls

Where projects commonly fail

New data are shown for the first time in the meeting.

The FDA should not be expected to review information it receives between its written feedback and the meeting; anything that needs review belongs in a Q-Sub supplement or in the later submission.

Silence is read as agreement.

The FDA does not discuss topics outside the Pre-Sub questions; if its feedback does not mention a topic, information on that topic may still be needed in the later submission, even if it was in the Pre-Sub.

The later submission does not name the Q-Sub.

Without the reference in the cover letter, the FDA does not link the two in its records, and finding the earlier feedback can delay the review. The submission also needs a section on how the feedback was addressed, including where a different approach was chosen.

The study starts on feedback more than a year old.

If more than one year has passed since FDA feedback on significant study design topics and the study has not begun, the guidance recommends confirming with the review division that the advice still applies.

Regulatory Affairs

Do any of these pitfalls apply to you?

In a first call we assess your situation and say what needs clarifying first in your case. Without obligation, reply usually within one working day.

FAQ

Frequently asked questions

A Pre-Sub asks for feedback before a planned submission. A SIR concerns a submission that is on hold: it discusses the approach to the deficiencies in a hold letter, such as an Additional Information letter for a 510(k) or De Novo or a Major Deficiency letter for a PMA. A SIR is not available for a Not Substantially Equivalent letter or while a file is under active review.

Sources
  • FDA Guidance: Requests for Feedback and Meetings for Medical Device Submissions: The Q-Submission Program (May 29, 2025), with Appendix 1 (Pre-Sub acceptance checklist) and Appendix 2 (example Pre-Sub questions), docket FDA-2018-D-1774: https://www.fda.gov/media/114034/download
  • FDA Draft Guidance: Electronic Submission Template for Medical Device Q-Submissions (May 29, 2025, draft), docket FDA-2025-D-1082: https://www.fda.gov/media/186664/download
  • FDA: Search for FDA Guidance Documents, status of both documents (retrieved November 1, 2026): https://www.fda.gov/regulatory-information/search-fda-guidance-documents
  • 21 CFR 812.2 (eCFR, current as of October 29, 2026): https://www.ecfr.gov/current/title-21/chapter-I/subchapter-H/part-812/subpart-A/section-812.2

Image notice: The images on this page were generated using artificial intelligence. They do not depict real people, places, or events.

Regulations & standards considered

  • FDA guidance: Requests for Feedback and Meetings for Medical Device Submissions: The Q-Submission Program (May 29, 2025)
  • FDA draft guidance: Electronic Submission Template for Medical Device Q-Submissions (May 29, 2025, draft)
  • 21 CFR 812.2(b) and (c) (nonsignificant risk studies and exempt investigations, basis of the Study Risk Determination)
  • FD&C Act Sec. 515(d)(3) (PMA Day 100 meeting, as cited in the Q-Sub guidance)
  • FD&C Act Sec. 513(g) (request for information on classification, outside the Q-Sub program)

Have a concrete project?

Briefly outline your situation. We'll respond with an initial assessment, usually within one business day.

Prefer direct? +49 89 4161170-0
contact@theentourage.de

  • Reply usually within one working day
  • 4 locations: DE · CH · IT · US
  • 100% life sciences